Product Features of R454 Growlink 96000Btu 28kW Industrial DC Inverter Chiller Dehumidifying Rooftop Commerce Air Conditioner Heating Cooling Thermal Pump -15Degree


Facing a multitude of variables may impact the best climate to achieve the intended quality of odor, potency, & color with the yield, in which humidity & temperature ranges are generally accepted, whose levels should be regulated at each stage to promote healthy growth.
RH & Temperature in the stages of Cannabis
Seedling: Water is absorbed mainly through leaves. Maintaining the conditions aids in nurturing the budding root systems without stress.
Vegetative: Mature roots are where plants now primarily absorb water. The settings help the plants adapt and grow robustly.
Early Flowering: Reduced humidity levels minimize mold risk, whose adjustments could support robust bud production & generally well-being.
Late Flowering: As buds develop & densify, the settings ensure no mold formation & set the stage for the harvest.
Post-Harvest: Perfecting the Cure: Even after the harvest, maintaining the ideal environment is pivotal. Proper curing ensures the preservation of the overall quality, bud’s flavor & potency, that a slow, consistent curing process is vital, what’s the difference between a flavorful, potent yield and a mediocre one.

TIPS: Above are generally accepted industry best practices, & every cultivator has your preferences to achieve the ultimate result on quality, odor, potency, & color, who are loose guidelines, & warmly welcome to discuss with cultivation experts & our engineers in R&D team for a proper solution to meet your expectations according to project.

Product Function Comparison & Differentiated Advantages
1. Mute Tech. Breakthrough: Compared with 55dB running noise of split A.C.s, it uses DC twin-rotor compressor + 3D noise reduction air duct design to control the noise ≤42dB, meeting EU residential area nighttime limit of 45dB.

2. AI Control Integration: Exclusively developed Multi-Control system is compatible with Google/Apple dual eco systems, GROWLINK APPs via BACnet, RS485 & more protocol options, supports voice control, power consumption forecasting & carbon footprint tracking, improves user experience compared to single APP control of others, simulates 100% ecological planting.
3. Multi-device linkage control: It supports access to intelligent system through Wi-Fi module (compatible with KNX, Zigbee, BAC net, RS485 & other protocols), & realizes cross-brand collaboration with fresh air systems, dehumidification & other equipment. For example, through growlink, a highly simulated complete indoor climate is formed to form the most suitable solution for plant growth.

4. Wide temp. range operation capability: It adopts advanced variable frequency compressor technology, which operates stably in extreme environments ranging from -15℃ to 52℃, ensuring efficient cooling/heating performance in Europe’s severe winter & high summer conditions, with an annual energy efficiency ratio (APF>4.8).
5. Photovoltaic compatible systems: Optional photovoltaic DC grid-connected module to achieve direct solar power drive, which reduces grid power consumption by 80% in southern Europe with abundant sunshine, meeting the requirements of EU Renewable Energy Directive II.

6. 0.5℃ precise temperature control: Equipped with a 32-bit microprocessor & PID algorithm, it monitors the indoor & outdoor temp. difference in real time & automatically adjusts compressor speed. Temp. fluctuation range is controlled within ±0.5℃, far exceeding the ±1.5℃ requirement specified in EN14511.
7. Module Installing Solution: Pre-installed refrigerant piping & quick docking kits, installation time shortened from 8H for traditional models to 3H, & its cost is reduced by 40%, solving the pain point of high labor costs in EU by our R454 Growlink 96000Btu 28kW Industrial DC Inverter Chiller Dehumidifying Rooftop Commerce Air Conditioner Heating Cooling Thermal Pump -15degree.
8. Latest ECO Commercial Gas Tech.: Core advantage of R454B (XL41) natural gas (GWP=446) adopted, both ECO & ErPrequests. With Japanese tech. twin-rotor compressor tech., its carbon footprint is reduced by 78%, meeting the EU F-Gas regulation 2030 emission reduction target requirements.

9. Full Serving Cycle Verification: Through 8760H of accelerated aging testing (equivalent to 10-year usage), including 2,000,000 on-off cycles, salt spray corrosion & other extreme environment simulations, its reliability is ensured in complex climates.
10.


Parameter of R454 Growlink 96000Btu 28kW Industrial DC Inverter Chiller Dehumidifying Rooftop Commerce Air Conditioner Heating Cooling Thermal Pump -15Degree
| Air to Air Air Conditioner Heat Pump 18kw 28kW 30kw 35kw | ||||||
| Nominal ton | (Ton) | 4.91 | 8.27 | 8.7 | 10.06 | |
| Item No. | #ADC-16XT | #ADC-26XT | #ADC-32XT | #ADC-40XT | ||
| Horse Power | HP | 6 | 8 | 10 | 12 | |
| Power Supply | V/Ph/Hz | 380-415/3/50-60 | 380-415/3/50-60 | 380-415/3/50-60 | 380-415/3/50-60 | |
| Cooling 1 | Capacity | BTU/h | 59011 | 95850 | 102350 | 120752 |
| Cooling | kW | 17.3 | 28 | 30 | 35.4 | |
| Power Input | kW | 4.5 | 6.9 | 7.9 | 9.3 | |
| EER1 | BTU/h/W | 13.2 | 13.9 | 13.6 | 13.2 | |
| Cooling 2 | Capaclty | Btu/h | 43788 | 72900 | 84000 | 86051 |
| Cooling | kW | 14.6 | 24.3 | 28 | 29 | |
| Power Input | kW | 4.7 | 7.8 | 8.9 | 10.6 | |
| EER2 | BTU/h/W | 9.32 | 9.35 | 9.4 | 9.32 | |
| Heating 1 | Capacity | kW | 21.5 | 34.8 | 36.6 | 44 |
| Power Input | kW | 8 | 12.5 | 13.7 | 16.5 | |
| COP 1 | BTU/h/W | 2.7 | 2.8 | 2.7 | 2.7 | |
| Heating 2 | Capaclty | kW | 17.7 | 29.2 | 30.6 | 36.1 |
| Power Input | kW | 6.6 | 10.6 | 11.3 | 13.4 | |
| COP 2 | 2.68 | 2.75 | 2.71 | 2.69 | ||
| Max.input consumption | kW | 5.9 | 10 | 12 | 14 | |
| Max.current | A | 12.6 | 20.3 | 24.8 | 25.6 | |
| Dehumidification capacity per hour | L/H | 8.2 | 13.2 | 15 | 16.8 | |
| Dehumidification capacity per day 24H | L/D | 196.8 | 316.8 | 360 | 403.2 | |
| Relative Humidity | % RH | 65 | 65 | 65 | 65 | |
| Performance | Indoor fan air flow | CFM | 2735 | 5800 | 6200 | 6500 |
| ESP | Pa | 80 | 80 | 80 | 80 | |
| Housing Panel Structure | GI steel, gray outer painting, singal side sound proof foam insulation, water proof top cover. | |||||
| Air filter | Nylon Concave Convex Mesh/Coarse Effect G3 | |||||
| Indoor fan | Type | Volute type centrifugal fan motor, DC type is available | ||||
| Compressor | Type | PANASONIC Dual-Rotary Type | PANASONIC Dual-Rotary Type | PANASONIC Dual-Rotary Type | PANASONIC Dual-Rotary Type | |
| Quantity | pc | 1 | 1 | 1 | 1 | |
| Outdoor Fan | Type | Ultra low noise dual inlet centrifugal type | ||||
| Rafrigerant gas | Type | R454B | R454B | R454B | R454B | |
| Valume | kg | Please contact us for more detail on this point. | Please contact us for more detail on this point. | Please contact us for more detail on this point. | Please contact us for more detail on this point. | |
| Refrigerant Control | Electronic expantion valve | Electronic expantion valve | Electronic expantion valve | Electronic expantion valve | ||
| Evaporator | Hydrophilic membrane copper tubes aluminum fins | |||||
| Condenser | Hydrophilic membrane copper tubes aluminum fins | |||||
| Controller | Control mainboard, LCD display , 15m control wires; Rs485 & main circuit breaker, WIFI 4G APP. | |||||
| Sound pressure level | dB(A) | 55 | 60 | 66 | 72 | |
| Amibient Temperature | Cooling | ℃ | 16-52 | 16-52 | 16-52 | 16-52 |
| Net Weight | kg | 150 | 180 | 305 | 330 | |
| Gross Weight | kg | 170 | 200 | 340 | 365 | |
| Unit Size | W*H*D | mm | 1330*700*750 | 1330*700*750 | 1510*1350*886 | 1510*1350*886 |
| Packing Size | W*H*D | mm | 1400*770*880 | 1400*770*880 | 1600*1450*1030 | 1600*1450*1030 |
| Qty/per 20’/40’/40H | pcs | 36/75/75 | 36/75/75 | 8/16/16 | 8/16/16 | |
| Cooling 1: Indoor air temp. 23℃ DB/15℃ WB; Outdoor air temp. 31℃ DB/20℃ WB. | ||||||
| Cooling 2: Indoor air temp. 27℃ DB/19℃ WB; Outdoor air temp. 35℃ DB/24℃ WB. | ||||||
| Heating 1: Indoor air temp. 24℃ DB/-℃ WB; Outdoor air temp. 11℃ DB/10℃ WB. | ||||||
| Heating 2: Indoor air temp. 20℃ DB/-℃ WB; Outdoor air temp. 7℃ DB/6℃ WB. | ||||||





Applications & Install Reference
project installation