Growlink R454 18KW 2800CFM Industry Chilling Dihumidifying Rooftop Commerce DC Converter Air Conditioning Heater Cooler Thermal Pump -15Dg

High EER 59000BTU App Wifi BACnet Commercial Cooling Industrial Freequency Inverter Air to Air Heater Cooler Thermal Pump 5℉

Cannabis/Marijuana/Hemp/Marihuana/Weed/Grass/Pot/Herb GrowRoom CE Mute Big Air Flow Modular RS485 Heated Cooling A. C. 12Lang HVAC Operate System

#ADC-16XS

  • 18kw Chilling Capacity, 22kw Heating Outlet;
  • high EER ≧13 & COP ≧2.7;
  • 5 years warranty;
  • Growlink Monitoring via BACnet + Wifi App Android or iOS;
  • Japanese Technology, PANASONIC Dual-rotary Compressor;
  • Noise in 1M ≤ 52dB;
  • Application for Cannabis/Marijuana/Hemp/Marihuana Grow Room;
  • DC Inverter System;
  • R454B gas refrigerant coolant (high performance and low environmental impact);
  • Low Temperature Working Ability, exceeding -15 degree air ambient temperature;
  • Air Chilling in Summer, Heating in Winter, 4-seasonal Ventilation and Dehumidification;
Quote Now

Product Description

店铺装修横幅banner 03 dc inverter industrial air conditioner
DC Inverter Industrial Air Conditioner

Product Features of Growlink R454 18KW 2800CFM Industry Chilling Dihumidifying Rooftop Commerce DC Converter Air Conditioning Heater Cooler Thermal Pump -15Degree

Ambient factors of Cultivating Cannabis & ideal Vapor Pressure Deficit (VPD)
Ambient factors of Cultivating Cannabis & ideal Vapor Pressure Deficit (VPD) for optimal plant growth
Against Pests & Diseases, Prevent Lights Overheating to reduce the chances of outbreaks, ensuring a healthy and abundant harvest.
Against Pests & Diseases, Prevent Lights Overheating to reduce the possibility of outbreaks, ensuring a healthy and abundant harvest.

Facing a multitude of variables may impact the best climate to achieve the intended quality of odor, potency, & color with the yield, in which humidity & temperature ranges are generally accepted, whose levels should be regulated at each stage to promote healthy growth.

RH & Temperature in the stages of  Cannabis

Seedling: Water is absorbed mainly through leaves. Maintaining the conditions aids in nurturing the budding root systems without stress.

Vegetative: Mature roots are where plants now primarily absorb water. The settings help the plants adapt and grow robustly.

Early Flowering: Reduced humidity levels minimize mold risk, whose adjustments could support robust bud production & generally well-being.

Late Flowering: As buds develop & densify, the settings ensure no mold formation & set the stage for the harvest.

Post-Harvest: Perfecting the Cure: Even after the harvest, maintaining the ideal environment is pivotal. Proper curing ensures the preservation of the overall quality, bud’s flavor & potency, that a slow, consistent curing process is vital, what’s the difference between a flavorful, potent yield and a mediocre one.

RH & Temperature in the stages of Cannabis
RH & Temperature in the stages of Cannabis, Seedling, Vegetative, Early & Late Flowering, Post-Harvest.

TIPS: Above are generally accepted industry best practices, & every cultivator has your preferences to achieve the ultimate result on quality, odor, potency, & color, who are loose guidelines, & warmly welcome to discuss with cultivation experts & our engineers in R&D team for a proper solution to meet your expectations according to project.

stages of cannabis plant
stages of cannabis plant

Product Function Comparison & Differentiated Advantages

1. Mute Tech. Breakthrough: Compared with 55dB running noise of split A.C.s, it uses DC twin-rotor compressor + 3D noise reduction air duct design to control the noise 42dB, meeting EU residential area nighttime limit of 45dB.

DC Inverter Advantages of Industrial Air to Air Air Conditioner
DC Inverter Advantages of Industrial Air to Air Air Conditioner

2. AI Control Integration: Exclusively developed Multi-Control system is compatible with Google/Apple dual eco systems, GROWLINK APPs via BACnet, RS485 & more protocol options, supports voice control, power consumption forecasting & carbon footprint tracking, improves user experience compared to single APP control of others, simulates 100% ecological planting.

3. Multi-device linkage control: It supports access to intelligent system through Wi-Fi module (compatible with KNX, Zigbee, BAC net, RS485 & other protocols), & realizes cross-brand collaboration with fresh air systems, dehumidification & other equipment. For example, through growlink, a highly simulated complete indoor climate is formed to form the most suitable solution for plant growth.

BACnet Integration Checklist Combines Industrial Air to Air DC Inverter Air Condtioner
BACnet Integration Checklist Combines with Industrial Air to Air DC Inverter Air Condtioner, fulltime monitoring by Growlink or alike APP.

4. Wide temp. range operation capability: It adopts advanced variable frequency compressor technology, which operates stably in extreme environments ranging from -15℃ to 52℃, ensuring efficient cooling/heating performance in Europe’s severe winter & high summer conditions, with an annual energy efficiency ratio (APF>4.8).

5. Photovoltaic compatible systems: Optional photovoltaic DC grid-connected module to achieve direct solar power drive, which reduces grid power consumption by 80% in southern Europe with abundant sunshine, meeting the requirements of EU Renewable Energy Directive II.

Smart Grid plus R454B Gas Air to Air DC Converter Industrial Air Conditioning Heat Pump
Smart Grid plus R454B Gas Air to Air DC Converter Industrial Air Conditioning Heat Pump

6. 0.5℃ precise temperature control: Equipped with a 32-bit microprocessor & PID algorithm, it monitors the indoor & outdoor temp. difference in real time & automatically adjusts compressor speed. Temp. fluctuation range is controlled within ±0.5℃, far exceeding the ±1.5℃ requirement specified in EN14511.

7. Module Installing Solution: Pre-installed refrigerant piping & quick docking kits, installation time shortened from 8H for traditional models to 3H, & its cost is reduced by 40%, solving the pain point of high labor costs in EU by our Growlink R454 18KW 2800CFM Industry Chilling Dihumidifying Rooftop Commerce DC Converter Air Conditioning Heater Cooler Thermal Pump -15degree.

8. Latest ECO Commercial Gas Tech.: Core advantage of R454B (XL41) natural gas (GWP=446) adopted, both ECO & ErPrequests. With Japanese tech. twin-rotor compressor tech., its carbon footprint is reduced by 78%, meeting the EU F-Gas regulation 2030 emission reduction target requirements.

R454B (XL41) GWP Reduction compares with other gases
R454B (XL41) GWP Reduction compares with other gases

9. Full Serving Cycle Verification: Through 8760H of accelerated aging testing (equivalent to 10-year usage), including 2,000,000 on-off cycles, salt spray corrosion & other extreme environment simulations, its reliability is ensured in complex climates.

10.

Different dc inverter air conditioner housing design according to Enthalpyincrease system,anti-salt spray coating (special for coastal areas), vertical/ horizontal housings, are Optional& unique modules with different air flow directions in air inlet & outlet for theneeds of different regional environments & engineering project sites.
Different dc inverter air conditioner housing design according to Enthalpyincrease system,anti-salt spray coating (special for coastal areas), vertical/ horizontal housings, are Optional& unique modules with different air flow directions in air inlet & outlet for theneeds of different regional environments & engineering project sites.

Product Parameter

Parameter of Growlink R454 18KW 2800CFM Industry Chilling Dihumidifying Rooftop Commerce DC Converter Air Conditioning Heater Cooler Thermal Pump -15Dg

Air to Air Air Conditioner Heat Pump 18kw 28kW 30kw 35kw
Nominal ton(Ton)4.918.278.710.06
Item No.#ADC-16XS#ADC-26XS#ADC-32XS#ADC-40XS
Horse PowerHP681012
Power SupplyV/Ph/Hz380-415/3/50-60380-415/3/50-60380-415/3/50-60380-415/3/50-60
Cooling 1CapacityBTU/h5901195850102350120752
CoolingkW17.3283035.4
Powir InputkW4.56.97.99.3
EER1BTU/h/W13.213.913.613.2
Cooling 2CapacltyBtu/h43788729008400086051
CoolingkW14.624.32829
Power InputkW4.77.88.910.6
EER2BTU/h/W9.329.359.49.32
Heating 1CapacitykW21.534.836.644
Power InputkW812.513.716.5
COP 12.72.82.72.7
Heating 2CapacltykW17.729.230.636.1
Power InputkW6.610.611.313.4
COP 22.682.752.712.69
Max.input consumptionkW5.9101214
Max.currentA12.620.324.825.6
Dehumidification capacity per hourL/H8.213.21516.8
Dehumidification capacity per day 24HL/D196.8316.8360403.2
Relative Humidity% RH65656565
PerformanceIndoor fan air flowCFM2735580062006500
ESPPa80808080
Housing Panel StructureGI steel, gray outer painting, singal side sound proof foam insulation, water proof top cover.
Air filterNylon Concave Convex Mesh/Coarse Effect G3
Indoor fanTypeVolute type centrifugal fan motor, DC type is available
CompressorTypePANASONIC Dual-rotary Type
Quantitypc1
Outdoor FanTypeUltra low noise dual inlet centrifugal type
Rafrigerant gasTypeR454BR454BR454BR454B
ValumekgPlease contact us for more detail on this point.
Refrigerant ControlElectronic expantion valveElectronic expantion valveElectronic expantion valveElectronic expantion valve
EvaporatorHydrophilic membrane copper tubes aluminum fins
CondenserHydrophilic membrane copper tubes aluminum fins
ControllerControl mainboard, LCD display , 15m control wires; Rs485 & main circuit breaker, WIFI 4G APP,(available for Growlink or the APP alike monitoring via BACnet).
Sound pressure leveldB(A)55606672
Amibient TemperatureCooling16-5216-5216-5216-52
Net Weightkg158188315340
Gross Weightkg178208350375
Unit SizeW*H*Dmm1250*680*15201250*680*15201350*680*15201350*680*1520
Cooling 1: Indoor air temp. 23℃ DB/15℃ WB; Outdoor air temp. 31℃ DB/20℃ WB.
Cooling 2: Indoor air temp. 27℃ DB/19℃ WB; Outdoor air temp. 35℃ DB/24℃ WB.
Heating 1: Indoor air temp. 24℃ DB/-℃ WB; Outdoor air temp. 11℃ DB/10℃ WB.
Heating 2: Indoor air temp. 20℃ DB/-℃ WB; Outdoor air temp. 7℃ DB/6℃ WB.
Product Apperance
Detailed Image of Growlink R454 18KW 2800CFM Industry Chilling Dihumidifying Rooftop Commerce DC Converter Air Conditioning Heater Cooler Thermal Pump -15Degree
Inner Views of R454B Coolant Air to Air Commercial Heat Pump Air Chiller Heating Conditioning
Inner Views of R454B Coolant Air to Air Commercial Heat Pump Air Chiller Heating Conditioning
Certificates of Room Heating Air Chilling DHWWarmepumpe R290 Heizung Warmwasser Pompe A Chaleur Monobloc EVI DC Inverter Air Source HEATED PUMP Water Heater
Certificates of Growlink R454 18KW 2800CFM Industry Chilling Dihumidifying Rooftop Commerce DC Converter Air Conditioning Heater Cooler Thermal Pump -15Degree
package and shipping methods for Low Temperature 8-10kw Monoblock type EVI DC Inverter Air Source Heated Pump Water Heater for Floor Heating Air Chilling and Tap Hot Water
package and shipping methods for Growlink R454 18KW 2800CFM Industry Chilling Dihumidifying Rooftop Commerce DC Converter Air Conditioning Heater Cooler Thermal Pump -15Dg

 

 

unit with wood packagine
unit with polywood packaging for Growlink R454 18KW 2800CFM Industry Chilling Dihumidifying Rooftop Commerce DC Converter Air Conditioning Heater Cooler Thermal Pump -15Dg

Applications & Install Reference

project installation

Industry Air Conditioner Installation
Industry Air Conditioner Installation
Customized Industry Air Source DC Converter Heat Pump Commerce Air Conditioner in Different Project Sites
Customized Industry Air Source DC Converter Heat Pump Commerce Air Conditioner in Different Project Sites
Modular R454B Coolant DC Inverter Air Conditioner Operate System in Project
Modular R454B Coolant DC Inverter Air Conditioner Operate System in Project
R454B Gas Commercial Air Conditioning DC Inverter Roof Chiller Heater at Project Site
R454B Gas Commercial Air Conditioning DC Inverter Roof Chiller Heater at Project Site
Customized R454B Coolant Industrial Air Conditioner Commercial DC Converter Heat Pump
Customized R454B Coolant Industrial Air Conditioner Commercial DC Converter Heat Pump

Any concerns, please feel free to leave us a message or send an inquiry on Growlink R454 18KW 2800CFM Industry Chilling Dihumidifying Rooftop Commerce DC Converter Air Conditioning Heater Cooler Thermal Pump -15Dg.

Send your message to us

    *Full Name

    *Country

    * Email

    Phone

    Message