X-COP 12kw Top EER 41000BTU/h House Heating Air Cooling Geothermal Water Ground Source to Water Heater Cooler DC Converter Thermal Pump

Water/Ground GEO DC Inverter Heated Pump Room Heater Cooler DHW

ADC-10HCG

  • 9kw Chilling Capacity, 11kw Heating Outlet;
  • high EER ≧3.0 & COP ≧4.0;
  • 5 years warranty;
  • Wifi App (Android or iOS);
  • Japanese Technology, PANASONIC Dual-rotary Compressor;
  • High Intelligent DC Inverter Operating System, LCD Display, 12Language is available for OEM/ODM.
  • Noise in 1M ≤ 52dB;
  • Application for Air/Water Cooling in Summer, Water/House Heating in Winter & 4-season Domestic Hot Water;
  • R290/R454B/R32 coolant gas refrigerant (high performance & low environmental impact);
  • Low Temperature Working Ability, exceeding -35 degree air ambient temperature.
Quote Now

Product Description

Product description of X-COP 12kw Top EER 41000BTU/h House Heating Air Cooling Geothermal Water Ground Source to Water Heater Cooler DC Converter Thermal Pump

Lower cost: A geothermal heat pump saves homeowners between 30-60% on heating costs and between 20-50% on cooling costs.

Fast return on investment: While geothermal systems can have higher initial costs than most other HVAC units, the overall cost savings will be seen within only a couple of years of your unit’s new construction.

Environmentally friendly: A geothermal system is one of the most eco-friendly ways to generate heat in and out of your home. Using less energy to operate, heat pumps lower your carbon footprint and lower air pollution caused by harmful greenhouse gases used in other systems. Quiet operation: There is no annoying noise when a heat pump turns on and off like with other types of units for heating and cooling.

Safe for you & your home: Since no combustive materials are used, a geothermal heat pump is safe to use and clean.

More comfortable: Geothermal heat pumps have been proven to improve the air quality in your home. If someone in your household has allergies or asthma, a heat pump unit will be much more pleasant as it operates to create an ideal balance of dehumidification and air purification.

Long lifespan: Indoor components of the heat pump can last up to 25 years, while the ground loop system can last up to 50 years. This significantly surpasses the lifespan of other HVAC units. Can be installed in all homes: Whether you install your heat pump in a new construction home or retrofit situations where there is existing ductwork, your home improvement efforts of installing a geothermal system will be well suited to any home environment.

Product Parameter
Parameter of X-COP 12kw Top EER 41000BTU/h House Heating Air Cooling Geothermal Water Ground Source to Water Heater Cooler DC Converter Thermal Pump
Item No#ADC-10HCG#ADC-12HCG#ADC-20HCG
Cooling capacity(kW)8.8 9.6 16 
Input power(kW)2.05 2.24 3.76 
Rated current (A)9.8 4.7 7.9
EER4.29 4.28 4.26
Heating capacity(kW)111220
Input power(kW)2.36 2.58 4.32
Rated current (A)11.3 5.4 9.1 
COP  4.66 4.65 4.63
Heat source circulation water capacity(L/H)300034005800
Use side pipe size(mm)DN25DN25DN25
Heat source pipe size(mm)DN25DN25DN25
IP Grade

(Level of protection)

IPX4IPX4IPX4
Anti-electric shock RateIII
Noise in 1 Mtr [dB(A)]≤52≤54≤58
Net weight (kg)9090125
Gross weight (kg)9696135
Metel plateGalvanized steel/Spray/Rose gold/Customized Color
Unit size(W*D*H)710*520*1000710*520*1000710*520*1000
CompressorPanasonic Dual-rotary
Refrigerant gasR32/R410A/R454B
Power supply220-240V/50-60Hz/1Ph380-415V/50-60Hz/3Ph380-415V/50-60Hz/3Ph
CondenserTube in tube heat exchanger / Plate type heat exchanger
EvaporatorPlate typePlate typePlate type
Expansion valveSANHUA EEV
AC contactor(220V-25A)(220V-12A)(220V-18A)
Thermorelay(12-18A)*1(6-9A)*1(9-13A)*1
Controller High Intelligent, DC Inverter, Motorola Chip, LCD screen display, Wifi AppHigh Intelligent, DC Inverter, Motorola Chip, LCD screen display, Wifi AppHigh Intelligent, DC Inverter, Motorola Chip, LCD screen display, Wifi App
Low-voltage switch0.15/0.32MPa0.15/0.32MPa0.15/0.32MPa
High-voltage switch3.0/3.6MPa 3.0/3.6MPa3.0/3.6MPa 
Power wire size3*2.5mm23*2.5mm2+2*1.5mm23*4mm2+2*2.5mm2

Working principle of X-COP 12kw Top EER 41000BTU/h House Heating Air Cooling Geothermal Water Ground Source to Water Heater Cooler DC Converter Thermal Pump

Geothermal heat pumps are much like the heat pump in the refrigerator – its purpose is to absorb the heat from the earth loop and concentrate it to a high enough temperature so that it can be effectively transmitted to the condition spaces within the building.

Just like the refrigerator, it has a series of closed-loop tubing through which a refrigerant fluid is recirculated.  The ground loop piping comes into close contact with cold – evaporator – side of the heat pump, transmitting some of its heat to refrigerant causing it to boil and vaporize and its temperature to rise slightly.  The vaporized fluid is then compressed which concentrates its heat, raising its temperature dramatically as it passes to the condenser side of heat pump.  Now the fluid is hot enough to transmit its heat to conditioned spaces within the building.  Before the fluid returns to the evaporator, it passes through an expansion valve which drops its temperature below 30oF so that it can absorb more heat from the ground loop.
A series of by-pass valves (not shown in the schematic) enables the evaporator and the condenser to switch positions, converting the heat pump to air-conditioning mode.
For Water Heating & Chilling of X-COP 12kw Top EER 41000BTU/h House Heating Air Cooling Geothermal Water Ground Source to Water Heater Cooler DC Converter Thermal Pump
geothermal water heater chiller thermal pump working principle for house heating air cooling
geothermal water heater chiller thermal pump working principle for house heating air cooling
Installation types of X-COP 12kw Top EER 41000BTU/h House Heating Air Cooling Geothermal Water Ground Source to Water Heater Cooler DC Converter Thermal Pump
There are several types of geothermal heat pump installations. Which type of unit will work best for your home will depend on the climate where you live, soil conditions, the size of your home that needs to be heated and cooled, and the local costs for the installation process.

Horizontal ground loops, vertical systems, and pond or lake loops are closed-loop systems that circulate heat through underground pipes. Open loop system pipes use a nearby water source like a well to circulate heat.

Horizontal system: Horizontal ground loops of layered coils and polyethylene pipes are buried in six-foot-deep trenches. This type of heat pump installation is ideal for approximately 2,000 square foot homes that have large ground space of up to 400 feet to build the trenches.

Vertical system: On properties with a limited amount of ground space, a vertical ground loop installation requires four-inch diameter holes to be drilled at 100 to 400 feet deep into the earth.
Pond/lake loop: Draws heat from a nearby lake or pond through a blanket of water that covers 10-foot-deep coils that are anchored onto racks to generate through the closed loop system.
Open loop: Open-loop pumps are water source heat pumps that use a nearby water source like a well. The pipe system cleans ground water to generate through the system and transform it into heat for your home.
 
working principle of water ground source heat pump
working principle of X-COP 12kw Top EER 41000BTU/h House Heating Air Cooling Geothermal Water Ground Source to Water Heater Cooler DC Converter Thermal Pump
Why choose us
1. DC fan motor cooperates + the aerodynamic anti-freeze fan blade, quiet, energy-saving, frequency-reducing, air-noise-reducing and durable.
2. TWO solders high-temp. welding, fully improving welds’ strength to reduce gas leakage. Mysteriouse flux miraculously improves auxiliary heat conduction, removing oxides, reducing welded surface tension & increasing the area, preventing re-oxidation & >2-time prolonging pipeline’s life.
3. Meticulous heat preservation process. High-quality thermal insulation tape combines with high-density Polyeaster rubber-plastic thermal insulation foam, conducting 360°thermal insulation around components & pipes, heat loss in 24H is <4℃ & seals much noise.
4. Pipe clamps are assembled to strenthen welding gap, reducing weld pressure, resisting & absorbing the shock to pipeline, reducing gas-leakage possibility rapidly, & reducing after-sales.. 
Certificates of DHW Heating Free Air Chilling DHW Warmepumpe R290 Heizung Warmwasser Pompe A Chaleur AIO DC Inverter Air Source HEATED PUMP Water Heater
Certificates of X-COP 12kw Top EER 41000BTU/h House Heating Air Cooling Geothermal Water Ground Source to Water Heater Cooler DC Converter Thermal Pump
r290 hp ce certificate
r290 heat pump CE certificate
舒玛详情 25 (package + shipping methods)
Package + shipping methods on X-COP 12kw Top EER 41000BTU/h House Heating Air Cooling Geothermal Water Ground Source to Water Heater Cooler DC Converter Thermal Pump
unit with wood packagine
unit with polywood packaging cases
Any concerns, please feel free to leave us a message or send an inquiry on X-COP 12kw Top EER 41000BTU/h House Heating Air Cooling Geothermal Water Ground Source to Water Heater Cooler DC Converter Thermal Pump

Send your message to us

    *Full Name

    *Country

    * Email

    Phone

    Message