266L Hot Water Heating System All In One Air Source Heat Pump Water Heater

AOI-35266L

  • Heat Pump water heater is especially designed for domestic Hot water, it can save you 70%-80% heating cost compared with other heating elements.
  • Double energy system by air source technology and smart electric water integrated technology;
  • All in one design,easy installation, save space;
  • Multi-protections including compressor high/low pressure protection, water flow protection, antifreeze protection  function to ensure the heat pump a good working performance;
  • Protecting Environment. There isn’t any burning gas from the water heater. The refrigerant won’t contaminate the Ozonosphere. So it benefits the society;
  • Supply water anytime, and not be affected by geographical and weather changing.
  • User-friendly to operate the Heat Pump
  • The Heat Pump is built for long hour operation 24/7.
  • Timer On and Timer Off is available on the Heat Pump
  • 150L,200L,266L and 300l capacities available
Quote Now

Features of 266L hot water heating system heat pump water heater

LED intelligent control
Large panel LED intelligent control multi-function mode selection, easy to operate, save time.

First class energy efficiency
Built-in electronic expansion valve, intelligent control of refrigerant flow, precise temperature control,energy saving and environmental protection.

Super mute
Sound insulation board sealed cabin, optimized design of noise reduction system of the whole machine, library-level mute.

Durable
International well-known brand heat pump compressor, stable operation at high and low temperature, safe and reliable.

Wire control
Beautiful and delicate control panel, which can be installed anywhere on the wall, easy to use and full of high-end style.

Parameter of 266L hot water heating system heat pump water heater

Item No#AOI-35200L#AOI-35266L#AOI-35300L
Heating capacity (kW) 3.53.53.5
BTU/H11947 11947 11947 
Input power (kW) 0.830.830.83
Rated current (A) 3.75 3.75 3.75 
COP4.22 4.22 4.22 
Hot water outlet (L/h)232 
Rated/Max outlet water temp.(℃)55/70
Work air temp.(℃) -10 to 45
IP Grade(Protect level)IPX4
Anti-electric shock Rate
Noise in 1M dB(A)≤48
Test condition: Input water temperature 15℃, outlet water temperature 70℃, dry bulb temperature 20℃, wet bulb temperature 15℃.
Housing MaterialABS+(Galvanized Steel)
Unit size (W*D*H) mm¢570*1785
CompressorPanasonic Rotary*1
RefrigerantR410
Power supply220-240V/1Ph/50Hz
EvaporatorHydrophilic Aluminium, Innergroove Tube
Heat exchangerDual External Copper Pipes Heat Exchanger
Four-way valveSHF-4
Expansion valveEEV
Motor (capacitance)YDK25/32
FanLow noise high efficiency axial (φ 190)
Air DirectionVertical
WIFIYES
Controller Single System(Intelligent, digital screen & touch button)
Low&High-voltage protectYes (3.0~2.4 MPa /0.05-0.15MPa)
Automatic defrosting systemYes
Low&High-pressure protect0.6MPa
Water Tank 200L266L300L
Inner Tank MaterialStainless SUS304 / Enamelled steel
Heat exchanger coil materialSUS316L
Auxiliary electric heater1500 w
Magnesium rod¢22*300 mm
Water Pipe Size(mm)DN 20
Wire Cable3*1.5 mm2 (16A leakage protection, EURO standard plug)
PackageStrong CTN with Foam & wooden supportStrong CTN with Foam & wooden support
Package Size645*645*1895 mm645*645*2180 mm715*715*2125 mm
N.W./G.W.(kg)96kg/101kg115.5kg/121.5kg135kg/142kg
Safety valveDN15DN20DN20
Recommended (for shower)4~5 people5~7 people6~8 people

Detailed images of 266L hot water heating system heat pump water heater

 

 

Installation attention of 266L hot water heating system heat pump water heater

①Choose the right path to move the unit;

②Try to move the unit as original case;

③If the unit installed in the building of the metal part,it must work for electrical insulation and comply with the relevant technical standards of electrical equipment.

  

(1) Waste heat is useful heat

The standard hear exchanger of the hot-water heat pump enables direct connection to a second heat generator,e.g. a solar heating system or a boiler.

(2) Dehumidification in the recirculating air mode

Dehumidified air in the laundry room supports laundry drying and prevents moisture-induced damage.

(3)Cooling in the recirculating air mode

The room air is extracted from the storage room or a wine cellar,subsequently cooled and dehumidified in the heat pump and finally re-introduced into the room.Recreation rooms,boiler rooms or utility rooms are ideal installation sites. The air ducts leading through warm sections must be insulated to prevent the formation of condensation.

(4)Variable change over of intake air

A duct system with integrated bypass flaps allows for variable utilization of the heat contained in the outside air or room air for the production of hot water.

Installation diagram of 266L hot water heating system heat pump water heater

 

Production Line of 266L hot water heating system heat pump water heater

Send your message to us

    *Full Name

    *Country

    * Email

    Phone

    Message